• Rotary Rubber Rheometer
  • Rotary Rubber Rheometer
  • Rotary Rubber Rheometer
  • Rotary Rubber Rheometer
Rotary Rubber Rheometer
  • ST-90

Rheometer is the most widely used instrument that once controlled the quality of rubber, rapid testing and basic research on rubber in the rubber processing industry, and can accurately measure parameters such as scorch time, positive rheometer time, sulfide, index and maximum and minimum torque.

Product Description

Rubber rheometer/rotary rheometer/rheometer is the most widely used instrument that once controlled the quality of rubber, rapid testing and basic research on rubber in the rubber processing industry, and can accurately measure parameters such as scorch time, positive rheometer time, sulfide, index and maximum and minimum torque.



Product Features

1. The non-rotor rheometer adopts the latest version of the latest domestic software, which has the characteristics of fast heating (within 3 minutes) and high temperature control. .

2. The non-rotor rheometer adopts α sealed cavity structure, which is in the leading position in the world.

3. The non-rotor vulcanizing machine adopts advanced alpha force sensor technology. :( sensor accuracy 0.001N.m).

4. The rotorless rheometer adopts advanced α-type sealed cavity structure, by introducing the sealing rotating cavity and fixed sealing cavity, while the general structure of the closed cavity and the open cavity is different, and its accuracy and requirements do not match the advanced. The repeatability of the airtight mold cavity is completely consistent, and it is in the leading position in the world.



Technical Data

Model

ST-90

Temperature control range

RT—200℃

Temperature fluctuation range

±0.15℃

Torque resolution

1/500000

Torque accuracy

0.3%

 Olk Unit

N.m, N.cm, N.inch, kN.m, 1,000 cm, kg.m, kg.cm, kg.inch, lp.m,lp.cm, lp. inch, g.m, g. cm, g. inch

Temperature display resolution.

0.01℃

Temperature recovery time after mold clamping.

< 1.5 minutes

Temperature units

C (degree ), F (Fallenheit), K (Kelvin degree)

Sampling rate

200 times/s

language

English, Chinese, Chinese traditions

Test Standards

GB/T 16584, American Materials Testing Standard D5289, ISO 6502

Calculate parameters

ts1,ts2,t10,t30,t50,t70,t90,Vc1,Vc2

Software interface

USB2.0

Print the content

Date, Time, Temperature, Vulcanization Curve, Temperature Curve, mL, MH, ts1, ts2, t10, t50, t90, Vc1, Vc2

Mail consultation
Please feel free to give your inquiry in the form below.We will reply you in 24 hours.