- ST-SS200
- + 10℃~60℃ ±1℃
- 5 ± 0.5%
- 30%-98%
- 2000mm×1000mm×500mmor custom made
The salt spray test is used to test the corrosion resistance of various materials after surface treatments, including coatings, electroplating, inorganic and organic films, anodizing, and anti-corrosion treatments such as rust-preventive oil. The inner and outer shells are integrally welded from PP sheets, ensuring corrosion resistance, impact resistance, easy cleaning, and zero leakage.
Product Description
The salt spray test is used to test the corrosion resistance of various materials after surface treatments, including coatings, electroplating, inorganic and organic films, anodizing, and anti-corrosion treatments such as rust-preventive oil. The inner and outer shells are integrally welded from PP sheets, ensuring corrosion resistance, impact resistance, easy cleaning, and zero leakage.
Standards
This equipment conforms to GB10587-89 "Technical Conditions for Salt Spray Testing Machines" and can perform various salt spray tests (NSS, ACSS, CASS) according to GB2423.17-93 "Basic Test Procedures for Electrical and Electronic Products - Test Ka: Salt Spray Test Method" and other equivalent standards such as GB/T 5170, GJB150, IEC, DIN, MIL, and ASTM.
Control Method :
1. Utilizing the Bernoulli principle, salt water is drawn and then atomized, resulting in uniform atomization without clogging or crystallization, ensuring consistent testing standards.
2. Nozzle: Made of special glass, the nozzle has a service life of up to 4200 hours and allows adjustment of spray volume and angle.
3. Spray Volume: The dual spray towers are located in the test chamber, ensuring uniform mist distribution. The volume can be adjusted to 1~2 ml/80cm²•h (16-hour average).
Technical Data
|
Test Space |
2000×1000×500mm |
|
Outer dimensions |
2400×1400×1000mm |
|
Temperature Resolution |
±0.1°C |
|
Temperature Control Accuracy |
±1.0°C |
|
Temperature Distribution Accuracy |
±2.0°C |
|
Temperature Uniformity |
≤2.0°C |
|
Temperature Volatility |
±1.0°C |
|
Salt Spray Deposition Volume |
1.5 ± 0.5ml/hr |
|
Spray Mode |
Single-tower spray; cycle time continuously adjustable |
|
Working Chamber Adjustable Temperature |
RT+5°C ~ 65°C; (RT refers to ambient temperature) |
|
Humidity Range |
85%~98%RH |
|
Cover Opening Mode |
Dual-cylinder automatic lifting |
Protect system :
1. Automatic power cut-off device at low water level
2. Automatic power cut-off device at overheating
3. Equipped with safety warning light
4. Jacket temperature (75℃) protection to prevent accelerated aging of the chamber (PP sheet shell)
5. Phase loss protection added to the three-phase input power supply
6. Fast-acting ceramic fuses (temperature resistant, flame-retardant) in the circuit
7. Equipment service life ≥ 8 years
Main Components:
• AC contactor: Schneider Electric
• Thermal relay: Schneider Electric
• AC relay: Schneider Electric
• Time relay: Taiwan
• Controller: Taiwan
• Over-temperature protector: Taiwan
• Main power switch: Schneider Electric • Solid-state relay: Taiwan
• Push-button switch: Taiwan
• Dry-burn protector: Italy